HS Si 4
Features/Options
- Thermoplastic enclosure
- Long life
- High shock resistance
- Hall sensor 1 NC/1 NO or 2 NC contacts
- Galvanically separated channels
- With pre-wired cable
Note
The actuator is not included in the delivery of the switches.
Product image

Technical data
| Standards | EN ISO 13849-1; IEC/EN 60947-5-2; IEC/EN 60947-5-3/PDF-M*; EN 954-1; EN 1088 |
|---|---|
| Enclosure | glass-fibre reinforced thermoplastic, ultramid A3XZG5, self-extinguishing |
| Defined object | Actuator MC 4 (order no. 05.00.8221) |
| Degree of protection | IP 67 to IEC/EN 60529 |
| Switching system | Hall sensor, 2 channels galvanically separated, semiconductor 1 NC/1 NO or 2 NC contacts |
| Connection | cable, 6 x AWG 26 |
Safety-relevant data: |
|
| EN 954-1 | Category 4 * |
| EN ISO 13849-1 | PL e |
| TM | max. 20 years |
| MTTFd | > 100 years |
Utilisation category |
DC-13, DC-12 |
| Ie/Ue | 40 mA / 24 VDC |
| Ue | 10 … 30 VDC |
| Ui | 75 VDC |
| Uimp | 1 kV |
| Residual current | ≤ 6 mA per channel |
| Voltage drop | ≤ 2.5 VDC |
| Switch-on/switch-off time | < 1 ms |
| Risk time | < 100 ms |
| Max. fuse rating | < 50 mA internal reversible fuse |
| Switching frequency | max. 1000 Hz |
| Degree of pollution | 3 |
| Overvoltage category | II |
| Ambient temperature | -20 °C … +70 ºC |
| Switching capacity: | |
| sao | 6 mm |
| sar | 20 mm |
* is only achieved in combination with a safety module |