HS Si 4

Features/Options

  • Thermoplastic enclosure
  • Long life
  • High shock resistance
  • Hall sensor 1 NC/1 NO or 2 NC contacts
  • Galvanically separated channels
  • With pre-wired cable

Note
The actuator is not included in the delivery of the switches.

Product image

 

Technical data

Standards EN ISO 13849-1;
IEC/EN 60947-5-2;
IEC/EN 60947-5-3/PDF-M*;
EN 954-1; EN 1088
Enclosure glass-fibre reinforced thermoplastic,
ultramid A3XZG5, self-extinguishing
Defined object Actuator MC 4
(order no. 05.00.8221)
Degree of protection IP 67 to IEC/EN 60529
Switching system Hall sensor, 2 channels galvanically separated, semiconductor
1 NC/1 NO or 2 NC contacts
Connection cable, 6 x AWG 26

Safety-relevant data:
EN 954-1 Category 4 *
EN ISO 13849-1 PL e
TM max. 20 years
MTTFd > 100 years

Utilisation category

DC-13, DC-12
Ie/Ue 40 mA / 24 VDC
Ue 10 … 30 VDC
Ui 75 VDC
Uimp 1 kV
Residual current ≤ 6 mA per channel
Voltage drop ≤ 2.5 VDC
Switch-on/switch-off time < 1 ms
Risk time < 100 ms
Max. fuse rating < 50 mA internal reversible fuse
Switching frequency max. 1000 Hz
Degree of pollution 3
Overvoltage category II
Ambient temperature -20 °C … +70 ºC
Switching capacity:
sao 6 mm
sar 20 mm

* is only achieved in combination with a safety module